MIL-DTL-62177E
4.6.2 Operating requirements verification.
4.6.2.1 Performance tests. The performance tests may be run concurrently with the
break-in specified in 3.3.1. The engine performance shall be required under the following
conditions:
a. The engine speeds shall be governed as specified in 3.3.4.
b. The engine shall function with external interface inputs as follows:
Fuel supply flow rate (minimum)
1400 lb (635 kg) per hour at 2400 rpm.
Fuel supply pressure (minimum)
3 psi.
Combustion air restriction
20 in. (0.51 m) of water
(maximum)
(1.5 in. Hg) at 2400 rpm.
Intake air filter
Equal to the requirements of
MIL-PRF-46736.
24 000 ft3/min (672 m3/min) approximate.
Cooling airflow
c. Diesel fuel conforming to A-A-52557, grade DF-2 shall be used. MIL-L-21260,
type I (-10 to 115°F) and MIL-L-46167 (-65 to 0°F) shall be used.
4.6.2.1.1 Governor. To determine conformance to 3.3.4, a bare/basic engine (see 6.5)
shall be operated at full power rpm, high idle rpm, and low idle rpm. On the AVDS1790-2DR
engine only, the rpm of the auxiliary drive operation shall be checked.
4.6.2.1.2 Gross hp. To determine conformance to 3.3.5, the engine shall be operated at
400 to 2450 rpm at the full power setting. The corrected gross hp shall be calculated and
recorded.
4.6.2.1.3 Torque. To determine conformance to 3.3.6, the engine shall be operated at
1800 and 2400 rpm at the full power setting. The corrected torque is a value that can be
calculated from the GCBHP.
4.6.2.1.4 Fuel consumption. To determine conformance to 3.3.7, the engine shall be
operated at 1800 and 2400 rpm at the full power setting under full load. The corrected fuel
consumption shall be calculated and recorded.
4.6.2.1.5 Oil pressure. To determine conformance to 3.3.8, the engine shall be operated
at 2400 rpm with the oil temperature at 140 to 250°F measured at the main oil gallery (oil cooler
outlet). The oil pressure shall be measured and recorded. Also, when the engine is idling, the oil
pressure shall be measured and recorded.
4.6.2.1.6 Intake manifold pressure. To determine conformance to 3.3.9, the engine shall
be operated at 2400 rpm at the full power setting. The intake manifold pressure shall be
measured and recorded.
13
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business